Sign In | Join Free | My burrillandco.com
Home > Salt Spray Test Chamber >

Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating

    Buy cheap Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating from wholesalers
     
    Buy cheap Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating from wholesalers
    • Buy cheap Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating from wholesalers
    • Buy cheap Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating from wholesalers
    • Buy cheap Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating from wholesalers
    • Buy cheap Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating from wholesalers

    Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating

    Ask Lasest Price
    Brand Name : iqualitrol
    Model Number : HL-120-CS
    Certification :
    Price :
    Payment Terms : T/T
    Supply Ability : 10 Sets per Month
    Delivery Time : 10 Working Days
    • Product Details
    • Company Profile

    Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating


    Programmable Environmental Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 for Electroplating


    Technical Data Download: iqualitrol Salt Spray Test Chamber HL-120-CS


    Brief Introduction:
    Salt Spray Test Chambers offer the most realistic and dependable corrosion test, widely used to test corrosion resistance of automotive, paint, surface coating, chemical, aerospace, electronic, car industry, offshore and defense industries.

    Salt spray testing is an accelerated corrosion test that produces a corrosive attack to coated samples in order to evaluate (mostly comparatively) the suitability of the coating for use as a protective finish. The appearance of corrosion products (rust or other oxides) is evaluated after a pre-determined period of time. Test duration depends on the corrosion resistance of the coating; generally, the more corrosion resistant the coating is, the longer the period of testing before the appearance of corrosion/ rust.

    The salt spray test is one of the most widespread and long established corrosion tests. ASTM B117 was the first internationally recognized salt spray standard, originally published in 1939. Other important relevant standards are ISO9227, JIS Z 2371 and ASTM G85.

    Acidified Salt Fog Test (cyclic) can be used to test the relative resistance to corrosion of aluminium alloys when exposed to a changing climate of acetic acid salt spray, followed by air drying, followed by high humidity, all at an elevated temperature.

    This test is also referred to as a MASTMAASIS test. Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises the following 3 part repeating cycle. 0.75 hours exposure to a continuous indirect spray of salt water solution, prepared in accordance with the requirements of the test standard and acidified (to pH 2.8 to 3.0) by the addition of acetic acid.

    This spray is set to fall-out on to the specimens at a rate of 1.0 to 2.0ml/80 cm²/hour. This is followed by 2.0 hours exposure to an air drying (purge) climate. This is followed by 3.25 hours exposure to a high humidity climate which gradually rises to between 65%RH and 95%RH. The entire test cycle is at a constant chamber temperature of +49C. The number of cycle repeats and therefore the test duration is variable.

    Features:
    1, Chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.
    2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.


    3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.


    4, Hot and moist air keeps the humidity in the test chamber conforms testing request.
    5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.

    Technical Specifications:

    Please note: HL-60-SS, HL-60-CS and HL-90-BS, HL-90-CS do not meet standard of ASTM B117.

    ModelHL-60-SSHL-90-BSHL-120-NSHL-160-NSHL-200-NS
    Model (Touch Screen)HL-60-CSHL-90-CSHL-120-CSHL-160-CSHL-200-CS

    Interior

    dimensions

    (mm)

    W600900120016002000
    D45060085010001200
    H400500500550600

    Exterior dimensions

    (mm)

    W11301460220026003000
    D630910120014501650
    H10701280145015501600
    Chamber Volume108 L270 L480 L800 L1440 L
    Solution Tank15L25 L40 L
    Power SupplyAC 220V 50HZAC 380V 50HZ
    Ambient temp. & humid. range+5℃ ~ +35℃ / <85%RH
    Testing TemperatureNSS ACSS 35℃±1℃ / CASS 50℃±1℃
    Air TemperatureNSS ACSS 47℃±1℃ /CASS 63℃±1℃
    Solution ConsistenceNaCl 5%
    PH ValueNASS ACSS:6.5~7.2 / CASS:3.0~3.2
    Temperature fluctuation≦±0.5℃
    Temperature uniformity≦2. 0℃
    Temperature deviation≦±2.0℃
    Spray quantum1.0~2.0(ml/80cm2/h)
    Chamber Materialpolyvinyl chloride (PVC)
    HeaterCorrosion-resistant titanium tube
    Temperature sensorPlatinum Resistance (PT-100)
    Safety deviceOver-temperature protection , leakage protection

    Note:
    1. The above specifications are for reference only, the actual specifications for the main quotation.
    2. Custom made is available according to customers’ special requirements.


    Quality Programmable Neutral Salt Spray Test Chamber HL-120-CS ASTM B117 For Electroplating for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Quality Control Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)